Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Dual |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Project | Specification | |
Line in | Voltage | 3-phase 380~480V - 15 %~+10%; |
Frequency | 50/60Hz ± 5% | |
Maximum unbalance | 3%; | |
Output | Voltage | 3-phase 0 ~100% input voltage; |
Frequency | 0 ~ 1600Hz ; | |
Main Control | Control mode | V/F, Vector control; |
Supported motor type | IM / PM | |
Starting torque | 0.5Hz 150%; | |
Overload | Heavy load type : 150% ~ 60s ; 180% ~ 3s | |
Switeching frequency | 2k~16kHz; | |
Speed resolution | Digital: 0.001Hz, Analog: 0.5‰ of the maximum setup; | |
Speed accuracy at speed Open loop | ±0.5% rated; | |
Source control command | Keyboard, Dlinputs, Bus communication; | |
Set frequency source | Keyboard, analoge, pulse inputs Bus communication; |
Acc / Dec | 4 groups paraineter for acc/dec: 0.05-6000.00s ; | ||
Project | Specification | ||
Basic functions | Speed open loop, speed closed loop, process closed loop control , torque open loop, torque closed loop , motor auto tuning, motor pre-excitation, automatic load compensation, automatic voltage regulation, acceleration and deceleration curve control, DC brake, AC brake, speed limit, torque limit, current limit, flying car start, instant stop, automatic reset, hybrid modulation function, LC filter compensation function, etc. ( Note : Speed close loop or torque control with speed sensor will active only when a control unit and PG card are installed ) | ||
Application function | Multistage speed control by terminals or PLC function, Sramp, mechanical brake, counter, process PID , jog etc. | ||
Protective function | Short circuit, ground fault, line phase loss, under voltage, over current, overload, over temperature, motor thenmal protection, motor phase loss, control wire broken etc. | ||
control terminal | 30-500 kW _ | DI input terminal | 5 Dis for NPN and voltage input; |
DO output terminal | 1 Dis for OC gate open output; | ||
RS485 communication terminal | 1 RS485 / Modbus, maximum 38400bit/s; |
AI output terminal | 2 AI of voltage and current input; | ||
AO output terminal | 2 AO of Current and voltage output; | ||
Operation keyboard | built-in | ||
Operation environment | Protection Lervel | IP20; | |
Workting temperature | Operating range -10 °C~60°C Nominal current to 40°C, derate form 40 ℃; | ||
Working humidity | 5%-85% (no condensation at 95%); | ||
Vibration | 1.14g | ||
Altitude | 1000m, derate from 1000m; | ||
Motor cable length | Shielded cable: 50m; Unshielded cable: 100m; |